InterOp:Connect/I-DEAS/I-DEAS Writer
From DocR18
The I-DEAS Writer component writes I-DEAS files. This component is in the form of shared libraries.
InterOp Connect supports translation of the following file formats and versions:
| Write | ||
|---|---|---|
| File Format | File Extension | Version Supported |
| I-DEAS | .mf1,.mf2 | I-DEAS MS12 NX Series m0 |
Contents |
Features
The I-DEAS Writer has the following features:
- Support for I-DEAS Assembly - The I-DEAS Writer supports translating the ACIS + XML files to I-DEAS Assembly.
Options for I-DEAS Writer
| Option | Default | Description |
|---|---|---|
| WriteTolerance | .00001 | This option controls the tolerance (in meters) of I-DEAS data while writing an I-DEAS file. |
Document
The I-DEAS Writer writes I-DEAS version 12 files.
Assembly
- Support for I-DEAS Assembly
The I-DEAS Writer supports translating the ACIS + XML files to I-DEAS Assembly.
BRep
The I-DEAS Writer supports the BRep representation.
Limitations
The I-DEAS Writer has the following limitations:
- File support
The translator can write only I-DEAS version 12 files.
- Unique file names
During I-DEAS translation, any existing I-DEAS files cannot be overwritten, hence every I-DEAS file should be given a unique name.
- Appending data in existing file
Before translation, a new empty model file should be opened in the I-DEAS session. Otherwise, translated data is appended to an existing, opened I-DEAS model file.
- Process locking
Process locking issues may occur when I-DEAS fails to clean certain files. Once these files are cleaned externally, this problem abates.
- The files that need cleaning include:
- .lck files in the same locations as the test files.
- Parts translated once to I-DEAS, whose .mf1 and .mf2 files from the earlier run have not been deleted. These files need to be deleted through the I-DEAS Data Manager.