Enhancements and Functionality Changes

General

  • Change in Default Value for Options Affecting B-rep Translation
The default value has been changed from false to true for the following options that affect B-rep translation. This change has been made for all applicable Reader and Writer components.

ACIS Reader/Writer Component

  • Support for Extremities of Dimensions
The SPAXPMI_DIMENSION class has an interface for getting extremity points of dimensions. Refer to Retrieving Dimension Extremities for more details.
  • Support for Importing Assembly PMI
The ACIS Writer imports PMI annotations created at assembly level in source assembly file. This is supported only in ACIS .asat or .asab assembly files. This is not supported in XML or flatten (.sat or .sab) route. Also, assembly PMI annotations attached onto workplanes or axis systems (local coordinate systems) of parts are not supported. Refer to the section Assembly PMI Annotations for more details.
  • Support for Material Names
The ACIS Writer imports Material Names of bodies. Refer to the section Material Names for more details.

CATIA V4 Reader/Writer Component

  • Deprecated Option: TranslateExtraEntities
The TranslateExtraEntities option has been deprecated and is no longer available.

CATIA V5 Reader Component

  • Support for Extremities of Dimensions
The CATIA V5 Reader can export extremity points for ordinate and linear dimensions. Refer to Dimension Extremities in CATIA V5 for more details.
  • CATIA V5 Toolkit Update
The CATIA V5 Reader has been updated with the CATIA V5 R19 toolkit.
  • Support for Hidden Instances in Assembly
The CATIA V5 Reader exports hidden instances from CATIA V5 assembly. Refer to the section Assembly for more details.
  • Support for Material Names
The CATIA V5 Reader now exports Material Names of bodies. Refer to the section Material Names for more details.
  • Support for Translating Non-semantic Stacked GeomTol PMI
The CATIA V5 Reader translates non-semantic stacked GD&T PMI. Refer to the section Non-semantic Stacked GeomTol PMI for more details.
  • Support for Translating Assembly PMI
The CATIA V5 Reader exports PMI annotations created at assembly level in CATProduct file. Assembly PMI annotations attached on workplanes or axis systems of CATPart files are not supported. Refer to the section Annotations in CATIA V5 for more details.

CATIA V5 Writer Component

  • Replacing non-ASCII characters in File Names
When you specify non-ASCII characters to a new CATIA V5 file name, the CATIA V5 Writer will replace those non-ASCII characters with "_" (underscores). This feature is applicable to both Assembly and Part files. Refer to No Support for File Names with Non-ASCII Characters for more details.
  • CATIA V5 Toolkit Update
The CATIA V5 Writer has been updated with the CATIA V5 R19 toolkit.
  • Support for Hidden Instances in Assembly
The CATIA V5 Writer imports hidden instances from source assembly. Refer to the section Assembly for more details.
  • Face Splitting Optimization
When a face's underlying surface is not continuous as per CATIA V5 requirements, CATIA V5 automatically splits that face and creates new faces according to its continuity requirements. In this release, face splitting while writing to a CATIA V5 file is optimized so that a fewer number of new faces are created after the split. Refer to the section CATIA V5 Writer B-rep for more details.

IGES Reader/Writer Component

  • Support for Reading IGES Files on Systems Running Under Non-English Locale
InterOp supports reading decimal data found in IGES files while running under a system locale whose decimal formatting rules differ from the English (United States) locale. Refer to Working with Localized File Paths for more details.

Inventor Reader Component

  • Support for Inventor 2009 version
InterOp supports translation of Part and Assembly files of Inventor 2009 version. Refer to the section Limitations for limitations of Inventor 2009 support.

Parasolid Reader/Writer Component

  • Support for Extremities of Dimensions
The Parasolid Reader/Writer includes an interface for returning extremity points of ordinate and linear dimensions. Refer to the section Dimension PMI for more details.
  • New Option: DeepHealing
The DeepHealing option controls the healing of data that has performance-expensive errors. Its default value is false.
  • Support for Material Names
The Parasolid Writer imports Material Names of bodies. Refer to the section Material Names for more details.
  • Support for Working Coordinate Systems
The Parasolid Writer imports Working (or Local) Coordinate Systems from source systems. Refer to the section Working Coordinate Systems for more details.
  • Support for Parasolid 21.0
InterOp Connect supports translation of Parasolid files versions 12.0 through 21.0.226.

Parasolid Manufacturing Option

  • Angular Dimension in Degree
The InterOp Parasolid Manufacturing Option returns the angular dimension value in degrees. In previous releases, the returned dimension value was in radians. Refer to Reference Angular Dimension for more details.

Pro/E Reader Component

  • Support for Wildfire 4 Version
The Pro/E Reader supports reading Wildfire 4 version part and assembly files. Refer to Format and Version Support for more details.
  • Removed Option: AllowNonmanifoldTopology
The option AllowNonmanifoldTopology has been deprecated beginning with R19 SP2 and removed in this release. Use TranslateSheetBodies instead.
  • Support for Free Curves
The Pro/E Reader supports reading of free curves and wires. Refer to Support for Free Curves for more details.

Pro/E Manufacturing Option

  • Support for Wildfire 4 PMI
The Pro/E Manufacturing Option supports reading PMI data from Pro/E Wildfire 4 files. Refer to Manufacturing Information for more details on Pro/E PMI support.
  • Linear Dimension Extremities Support
InterOp Connect supports linear dimension extremities for Pro/E. Refer to the section Support for Linear Dimension Extremities for more details.
  • PMI with No Leader
InterOp Connect behavior for translating PMI with no leader has changed. In previous releases, Connect would return a leader having coordinate (0,0,0) for head and tail points, but now correctly returns an empty leader list. Refer to Support for Pro/E PMI Display Information for more details.
  • Filtered Extra PMI Datums of Free Curves
In earlier releases, InterOp used to translate extra PMI datums for free curves. This has been fixed in this release. Thus, you might notice a reduction in the number of PMI datums translated.

SolidWorks Reader Component

  • Support for Reading Unit of SolidWorks Part and Assembly Files
The InterOp SolidWorks Reader supports reading unit information from part and assembly files. Refer to Limited Support for Reading Units in Part or Assembly Files for more details.
  • Support for Unicode in SolidWorks Reader
The InterOp SolidWorks Reader supports reading part and assembly files' paths having localized strings without setting the locale. Refer to Working with Localized File Paths for more details.
  • Support for SolidWorks 2009
InterOp Connect supports SolidWorks version 2009. Refer to the section SolidWorks Reader for more details.

STEP Reader/Writer Component

  • Support for Reading/Writing Localized Strings in STEP Files
The InterOp STEP Reader/Writer supports reading/writing localized strings in STEP files as described in Localized Text in STEP Files.
  • Option Default Value Change: WriteAssemAsCtxtDepShapeRep
The default value of for the WriteAssemAsCtxtDepShapeRep option has changed to true. Refer to WriteAssemAsCtxtDepShapeRep for more details.

NX Reader Component

  • Support for Extremities of Dimensions
The NX Reader can export extremity points for ordinate and linear dimensions. Refer to Limited Support for Dimension Line Extremities for more details.
  • Support for Unicode
The InterOp NX Reader supports reading part and assembly files' paths having localized strings without setting the locale. Refer to Working with Localized File Paths for more details.
  • Support for NX 6 version
The NX Reader supports B-rep, Assembly, and PMI data of NX 6 version files. Refer to the section Limitations for limitations of NX.

NX Manufacturing Option

  • Support for NX 6 PMI
The NX Manufacturing Option supports reading PMI data from NX 6 files. Refer to Manufacturing Information for more details on NX PMI support.

VDA-FS Reader/Writer Component

  • Support for Reading VDA-FS Files on Systems Running Under Non-English Locale
InterOp supports reading decimal data found in VDA files while running under a system locale whose decimal formatting rules differ from the English (United States) locale. Refer to Working with Localized File Paths for more details.

XML E-BOM Reader Component

  • Support for Writing "Visibility" and "Suppressed" Attributes
InterOp supports writing "Visibility" and "Suppressed" attributes to child nodes in XML assembly structures. These are optional attributes which are written only in case that "Visibility" has a value of false and "Suppressed" has a value of true. Refer to Hidden Instances for more details.
  • Support for Hidden Instances in Assembly
The XML E-BOM Reader exports hidden instances from XML assembly. Refer to the section Hidden Instances for more details.
  • Unit Support
The XML E-BOM Reader supports reading unit information from XML files. If there is no unit information in the XML file, then the millimeter unit is assumed. Refer to Units for more details.

XML E-BOM Writer Component

  • Support for Writing "Visibility" and "Suppressed" Attributes
This release supports writing "Visibility" and "Suppressed" attributes to child nodes in XML assembly structures. That is, if the option "TranslateHiddenEntities" is set to true then the hidden instances from the source assembly will be written to XML but with value of false assigned to the attribute "Visibility". These are optional attributes which are written only if "Visibility" has a value of false and "Suppressed" has a value of true. Refer to Hidden Instances for more details.
  • Support for Unicode
The InterOp XML E-BOM Writer supports writing XML files with UTF-8 encoding. Beginning with this release, XML files will contain only UTF-8 encoding. Refer to Working with Localized File Paths for more details.
  • Instance Files Are Written in Binary Mode
By default, the XML E-BOM Writer writes instance files in binary format. That is, a .sab file is generated for ACIS and .x_b is generated for Generic formats. The new option BinaryTargetDocument enables you to write the instance files in binary or text mode.
  • Support for Hidden Instances in Assembly
The XML E-BOM Writer imports hidden instances from source assembly. Refer to the section Hidden Instances for more details.
  • Unit Support
The XML E-BOM Writer supports writing unit information to XML files. Refer to Units for more details.
  • Support for Mixed Mode Translation
The XML E-BOM Writer supports generating XML files which reference a Parasolid document. Refer to Mixed Mode Translation for more details.
  • Support for Missing Parts and Sub-assemblies
The XML E-BOM Writer supports missing parts and missing sub-assemblies information when translating from Pro/E and NX assembly files. Refer to Missing Parts and Sub-assemblies for more details.